CConnMonDeleteConnection Class Reference

Link against: ConnMon.lib

Capability Information

Required Capabilities

None

Exceptions

ReadDeviceData to call

IMPORT_C void GetIntAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, TInt& aValue, TRequestStatus& aStatus );

IMPORT_C TInt SetIntAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, const TInt aValue ) const;

with aAttribute set to KProtocolType.

NetworkServices and NetworkControl to call

IMPORT_C void GetBoolAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, TBool& aValue, TRequestStatus& aStatus );

IMPORT_C TInt SetBoolAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, const TBool aValue ) const;

with aAttribute KConnectionStop or KConnectionStopAll.

ReadDeviceData to call

IMPORT_C void GetStringAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, TDes& aValue, TRequestStatus& aStatus ) const;

IMPORT_C TInt SetStringAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, const TDes& aValue ) const;

with aAttribute set to KAccessPointName or KNetworkName.

ReadUserData to call

IMPORT_C void GetStringAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, TDes& aValue, TRequestStatus& aStatus ) const;

IMPORT_C TInt SetStringAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, const TDes& aValue ) const;

with aAttribute set to KTelNumber.

NetworkControl to call

IMPORT_C void GetPckgAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, TDes8& aValue, TRequestStatus& aStatus ) const;

IMPORT_C TInt SetPckgAttribute( const TUint aConnectionId, const TUint aSubConnectionId, const TUint aAttribute, const TDes8& aValue ) const;

with aAttribute set to KClientInfo.


#include <
rconnmon.h>

Inherits CConnMonEventBase.


Detailed Description

This event is triggered when a connection has been deleted.

The connection ID passed in the event is the connection ID of the deleted connection.

Dll CONNMON.LIB

Public Member Functions

 CConnMonDeleteConnection (const TUint aConnectionId, const TUint aDownlinkData, const TUint aUplinkData, const TBool aAuthDelete)
 Constructor.
 ~CConnMonDeleteConnection ()
 Destructor.
IMPORT_C TUint DownlinkData () const
 Gets the downlink data volume.
IMPORT_C TUint UplinkData () const
 Gets the uplink data volume.
IMPORT_C TBool AuthoritativeDelete () const
 Checks if the connection was stopped in an authoritative way.

Constructor & Destructor Documentation

CConnMonDeleteConnection::CConnMonDeleteConnection const TUint  aConnectionId,
const TUint  aDownlinkData,
const TUint  aUplinkData,
const TBool  aAuthDelete
 

Constructor.

Parameters:
aConnectionId Connection ID.
aDownlinkData Downlink data volume.
aUplinkData Uplink data volume.
aAuthDelete Was connection stopped in an authoritative way.
CConnMonDeleteConnection::~CConnMonDeleteConnection  ) 
 

Destructor.


Member Function Documentation

IMPORT_C TBool CConnMonDeleteConnection::AuthoritativeDelete  )  const
 

Checks if the connection was stopped in an authoritative way.

ETrue will be returned if the user has deactivated the connection by using Connection Monitor or if some application has issued RConnection::Stop( RConnection::EStopAuthoritative ).

Returns:
ETrue if connection has been deactivated in an authoritative way, otherwise returns EFalse.
IMPORT_C TUint CConnMonDeleteConnection::DownlinkData  )  const
 

Gets the downlink data volume.

Returns:
Downlink data volume in bytes.
IMPORT_C TUint CConnMonDeleteConnection::UplinkData  )  const
 

Gets the uplink data volume.

Returns:
Uplink data volume in bytes.

The documentation for this class was generated from the following file:

Copyright © Nokia Corporation 2001-2007